| Sign In | Join Free | My futurenowinc.com | 
 | 
Brand Name : VICTOR
Model Number : VICTOR 26
Certification : CE
Place of Origin : CHINA
MOQ : 1pcs
Price : USD1250/pc
Payment Terms : T/T, Western Union, L/C, Paypal
Supply Ability : 1000pcs available
Delivery Time : 5 to 30 days
Packaging Details : 6pcs/Carton; Carton Size: 53*40.5*31cm
Color : Blue or Orange and Black
Size : 206 × 97× 60 mm
Product Name : Multifunction Process Calibrator
Model No. : VICTOR 26
Packing Details : 6pcs/Carton; Carton Size: 53*40.5*31cm
Accuracy : 0.01% accuracy
Weight : Approx. 633g (including batteries)
Protection : IP65
DCI output manual-step, auto-step and auto-ramping output functions.
Built-in 24V loop circuit.
Input Measurement Function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% readings + % range)]
| measurement function | range | measurement range | resolution | accuracy | remark | 
| DC voltage DCV | 50mV | -5.000mV~ 55.000mV | 1μV | 0.01+0.01 | Input resistance: about 100MΩ | 
| 500mV | -50.00mV~ 550.00mV | 10μV | 0.01+0.01 | ||
| 5V | -0.5000V~ 5.5000V | 0.1mV | 0.01+0.01 | Input resistance: about 1MΩ | |
| 30V | -5.000V~ 35.000V | 1mV | 0.01+0.01 | ||
| DC current DCI | 50mA | -5.000mA~ 55.000mA | 1μA | 0.01+0.01 | shunt resistance: about 10Ω | 
| Ohms OHM (4W) | 500Ω | 0.00Ω~550.00Ω | 0.01Ω | 0.01+0.01 | 500Ω about 1mA simulation 5KΩ about 0.1mA simulation open-loop voltage: about 2.5V wire resistance is excluded in the accuracy | 
| 5KΩ | 0.0000 KΩ~ 5.5000KΩ | 0.1Ω | 0.01+0.01 | ||
| frequency FREQ | 50KHz | 3Hz~50.00000KHz | 0.01Hz | 0.01+0.00004 | input resistance: more than 100 kΩ frequency sensitivity: square wave is 3V Vp-p at least 50% duty ratio | 
| CPM | 180~3000000 CPM | 1CPM | ±2个字 | ||
| Thermal couple TC | R* | 0°C~1767°C | 1°C | 0~500℃ : 1.8℃ 500~1767℃ : 1.5℃ | Employ ITS-90 temperature standard Errors for cold-end compensation is excluded in the accuracy | 
| S* | 0°C~1767°C | ||||
| K | -100.0°~1372.0°C | 0.1°C | -100.0~0.0℃ : 1.2℃ 0.0~1372.0℃ : 0.8℃ | ||
| E | -50.0°C~1000.0°C | -50.0℃~0.0℃ : 0.9℃ 0.0~1000.0℃ : 1.5℃ | |||
| J | -60.0°C~1200.0°C | -60.0~0.0℃ : 1.0℃ 0.0~1200.0℃ : 0.7℃ | |||
| T | -100.0°C~400.0°C | -100.0~0.0℃ : 1.0℃ 0.0~400.0℃ : 0.7℃ | |||
| N | -200.0°~1300.0°C | -200.0~0.0℃ : 1.5℃ 0.0~1300.0℃ : 0.9℃ | |||
| B* | 600°C~1820°C | 1°C | 600~800℃ : 2.2℃ 800~1000℃ : 1.8℃ 1000~1820℃ : 1.4℃ | ||
| L | -60.0°C~900.0°C | 0.1°C | -60.0~0.0℃ 0.7℃ 0.0~900.0℃ 0.5℃ | ||
| U | -100.0°C~600.0°C | 0.1°C | -100.0~0.0℃ 0.7℃ 0.0~600.0℃ 0.5℃ | ||
| Resistance temperature RTD 
 | Pt100 385 | -200.0°C~800.0°C | 0.1°C | -200.0~0.0℃ : 0.5℃ 0.0~400.0℃ : 0.7℃ 400.0~800.0℃ : 0.8℃ | Employ ITS-90 temperature standard Errors due to the mismatch of lead resistance for lead resistance, 3-wired or 4-wired measurements are excluded in the accuracy | 
| Pt1000 385 | -200.0°C~630.0°C | -200.0~100.0℃: 0.3℃ 100.0~300.0℃ : 0.5℃ 300.0~630.0℃ : 0.7℃ | |||
| Pt200 385 | -200.0°C~630.0°C | -200.0~100.0℃: 0.8℃ 100.0~300.0℃ : 0.9℃ 300.0~630.0℃ : 1.0℃ | |||
| Pt500 385 | -200.0°C~630.0°C | -200.0~100.0℃: 0.4℃ 100.0~300.0℃ : 0.5℃ 300.0~630.0℃ : 0.7℃ | |||
| Cu10 | -100.0°C~260.0°C | 1.8℃ | |||
| Cu50 | -50.0°C~150.0°C | 0.7℃ | |||
| Pulse counting PULSE | 100000 cycles | 1~100000cycles | 1cycle | ±2个字 | see the related indexes for frequency | 
| switch volume measurement SWITCH | CLOSE / OPEN | about 1mA simulation short circuit displays CLOSE open circuit displays OPEN the threshold value is about 200~300Ω | |||
| Continuity test CONNECT | 500Ω | ≤ 50Ω vocalize | 0.01Ω | 500Ω about 1mA simulation | |
| Loop supply LOOP | 24 V | 10% | short circuit protection Max circuit : 22 mA Max input voltage: 30 V DC output resistance: 250Ω nominal value | 
Other features:
Simulation Output Function [adapt to one year after calibration 23℃±5℃, 20~70%RH ,accuracy=±(% settings + range %)]
| Output function | range | Output range | resolution | accuracy | remark | ||||||
| DC voltage DCV | 100mV | -10.000~110.000mV | 1μV | 0.01+0.01 | Max output current 0.5mA | ||||||
| 1V | -0.10000~1.10000V | 10μV | 0.01+0.01 | Max output current 2mA | |||||||
| 10V | -1.0000~11.0000V | 0.1mV | 0.01+0.01 | Max output current 5mA | |||||||
| Dc current DCmA | 30mA | 0.000~33.000mA | 1μA | 0.01+0.01 | In 33mA, the Max load is 1KΩ resistance in simulate transmitter,external power supply 5~28V | ||||||
| Ohmn OHM | 400Ω | 0.00~400.00Ω | 0.01Ω | 0.01+0.01 | simulate current is ±0.05~0.3mA simulate current is ±0.1~0.5mA , plus 0.1Ω additional error wire resistance is excluded in the accuracy | ||||||
| 4KΩ | 0.0000~4.0000 KΩ | 0.1Ω | 0.01+0.01 | ±0.05~0.3mA simulate current wire resistance is excluded in the accuracy | |||||||
| Thermal couple TC | R* | 0°C~1767°C | 1°C | 0~100℃ 10~1767℃ 0~100℃ 100~1767℃ | 1.5℃ 1.2℃ 1.5℃ 1.2℃ | Employ ITS-90 temperature standard 
 Errors for cold-end compensation is excluded in the accuracy | |||||
| S* | 0°C~1767°C | ||||||||||
| K | -200.0°C~1372.0°C | 0.1°C | -200.0~-100.0℃ -100.0~400.0℃ 400.0~1200.0℃ 1200.0~1372.0℃ | 0.6℃ 0.5℃ 0.7℃ 0.9℃ | |||||||
| E | -200.0°C~1000.0°C | -200.0~-100.0℃ -100.0~600.0℃ 600.0~1000.0℃ | 0.6℃ 0.5℃ 0.4℃ | ||||||||
| J | -200.0°C~1200.0°C | -200.0~-100.0℃ -100.0~800.0℃ 800.0~1200.0℃ | 0.6℃ 0.5℃ 0.7℃ | ||||||||
| T | -250.0°C~400.0°C | -250.0~400.0℃ | 0.6℃ | ||||||||
| N | -200.0°C~1300.0°C | -200.0~-100.0℃ -100.0~900.0℃ 900.0~1300.0℃ | 1.0℃ 0.7℃ 0.8℃ | ||||||||
| B* | 600°C~1820°C | 1°C | 600~800℃ 800~1820℃ | 1.5℃ 1.1℃ | |||||||
| L | -200.0°C~900.0°C | 0.1°C | -200.0~0.0℃ 0.0~900.0℃ | 0.7℃ 0.5℃ | |||||||
| U | -200.0°C~600.0°C | 0.1°C | -200.0~0.0℃ 0.0~600.0℃ | 0.7℃ 0.5℃ | |||||||
| resistance temperature RTD | Pt100 385 | -200.0°C~800.0°C | 0.1°C | -200.0~0.0℃ 0.0~400.0℃ 400.0~800.0℃ | 0.3℃ 0.5℃ 0.8℃ | Employ ITS-90 temperature standard 
 Pt100,Cu50,Cu10 simulate current is: ±0.5~3mA when the simulate current is : ±0.1~0.5mA, add additional 0.5℃ error. 
 Pt200,Pt500,Pt1000 simulate current is ±0.05~0.3mA wire resistance is excluded in the accuracy | |||||
| Pt200 385 | -200.0°C~630.0°C | -200.0~100.0℃ 100.0~300.0℃ 300.0~630.0℃ | 0.8℃ 0.9℃ 1.0℃ | ||||||||
| Pt500 385 | -200.0°C~630.0°C | -200.0~100.0℃ 100.0~300.0℃ 300.0~630.0℃ | 0.4℃ 0.5℃ 0.7℃ | ||||||||
| Pt1000 385 | -200.0°C~630.0°C | -200.0~100.0℃ 100.0~300.0℃ 300.0~630.0℃ | 0.2℃ 0.5℃ 0.7℃ | ||||||||
| Cu10 | -10.0°C~250.0°C | 1.8℃ | |||||||||
| Cu50 | -50.0°C~150.0°C | 0.6℃ | |||||||||
| frequency FREQ | 100Hz | 1.00 Hz ~110.00Hz | 0.01Hz | ±2 bytes | 1~11 Vp-p accuracy of square wave level ±5%reading +0.5V 50% duty ratio load >100KΩ | ||||||
| 1KHz | 0.100 KHz ~1.100KHz | 1Hz | ±2 bytes | ||||||||
| 10KHz | 1.0KHz~11.0KHz | 0. 1KHz | ±2 bytes | ||||||||
| 50KHz | 10KHz~50KHz | 2KHz | ±5 bytes | ||||||||
| CPM | 60~1200 CPM | 1CPM | ±2CPM | ||||||||
| Pulse counting PULSE | 100Hz | 1~100000cycles | 1cyc | ±2 bytes | see related index in frequency | ||||||
| 1KHz | |||||||||||
| 10KHz | |||||||||||
| Switch volume SWITCH | 100Hz | 1.00Hz~110.00Hz | 0.01Hz | ±2 bytes | see related index in frequency FET switch Max switch DC voltage/current: +28 V/50mA | ||||||
| 1KHz | 0.100KHz~1.100KHz | 1Hz | |||||||||
| 10KHz | 1.0KHz~11.0KHz | 0.1KHz | |||||||||
| 50KHz | 10KHz~50KHz | 2KHz | |||||||||
| Project | Model Performance parameters | VICTOR 26 | VICTOR 26H | |
| Source | DC millivolt | Range | -5 ~ 110mV | -5 ~ 110mV | 
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uV | 1uV | ||
| DC voltage | Range | -1 ~ 11V | -1 ~ 11V | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 10uV/0.1mV | 10uV/0.1mV | ||
| DC current | Range | 0 ~ 33mA | 0 ~ 33mA | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uA | 1uA | ||
| Sink current | Range | 0 ~ 33mA | 0 ~ 33mA | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uA | 1uA | ||
| External power supply | 5 ~ 28V | 5 ~ 28V | ||
| Resistance | Range | 0 ~4KΩ | 0 ~4KΩ | |
| Accuracy= ±(% of the set value+% of range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 0.01Ω/0.1Ω | 0.01Ω/0.1Ω | ||
| Thermocouple | Range | R/S/K/E/J/T/B/N/L/U | R/S/K/E/J/T/B/N/L/U | |
| Accuracy | 0.4℃ | 0.4℃ | ||
| Resolution | 0.1℃/1℃ | 0.1℃/1℃ | ||
| RTD | Range | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | |
| Accuracy | 0.2℃ | 0.2℃ | ||
| Resolution | 0.1℃ | 0.1℃ | ||
| Frequency (Hz) | Range | 1Hz ~110KHz | 1Hz ~110KHz | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | 0.01Hz/1Hz/0.1KHz/2KHz | ||
| Frequency(CMP) | Range | 60~1200 CPM | 60~1200 CPM | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 1CPM | 1CPM | ||
| Pulse | Frequency | 1Hz ~10KHz | 1Hz ~10KHz | |
| Range | 1 ~100000cyc | 1 ~100000cyc | ||
| Accuracy | ±2words | ±2words | ||
| Resolution | 1cyc | 1cyc | ||
| Switch | Range | 1Hz ~110KHz | 1Hz ~110KHz | |
| Accuracy | ±2 | ±2 | ||
| Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | 0.01Hz/1Hz/0.1KHz/2KHz | ||
| Pressure | Range | Depends on the pressure module | Depends on the pressure module | |
| Accuracy= ±(% of the set value+% of range) | Depends on the pressure module | Depends on the pressure module | ||
| Resolution | 5 digit display | 5 digit display | ||
| Measurement | DC millivolt | Range | -5 ~ 550mV | -5 ~ 550mV | 
| Accuracy= ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uV/10uV | 1uV/10uV | ||
| DC voltage | Range | -0.5 ~ 35V | -0.5 ~ 35V | |
| Accuracy= ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 0.1mV/1mV | 0.1mV/1mV | ||
| DC current | Range | -5 ~ 55mA | -5 ~ 55mA | |
| Accuracy ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 1uA | 1uA | ||
| Resistance | Range | 0 ~5.5KΩ | 0 ~5.5KΩ | |
| Accuracy= ±( % of Reading+ % of Range) | 0.01%+0.01% | 0.01%+0.01% | ||
| Resolution | 0.01Ω/0.1Ω | 0.01Ω/0.1Ω | ||
| Thermocouple | Range | R/S/K/E/J/T/B/N/L/U | R/S/K/E/J/T/B/N/L/U | |
| Accuracy | 0.7℃ | 0.7℃ | ||
| Resolution | 0.1℃/1℃ | 0.1℃/1℃ | ||
| RTD | Range | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50 | |
| Accuracy | 0.4℃ | 0.4℃ | ||
| Resolution | 0.1℃ | 0.1℃ | ||
| Frequency (Hz) | Range | 3Hz ~50KHz | 3Hz ~50KHz | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 0.01Hz | 0.01Hz | ||
| Frequency(CMP) | Range | 180~3000000 CPM | 180~3000000 CPM | |
| Accuracy | ±2words | ±2words | ||
| Resolution | 1CPM | 1CPM | ||
| Switch | Range | CLOSE/OPEN | CLOSE/OPEN | |
| Threshold | 200 ~300Ω | 200 ~300Ω | ||
| Pressure | Range | Depends on the pressure module | Depends on the pressure module | |
| Accuracy= ±( % of Reading+ % of Range) | Depends on the pressure module | Depends on the pressure module | ||
| Resolution | 5 digit display | 5 digit display | ||
| Continuity beeper | Range | 0 ~500Ω | 0 ~500Ω | |
| Accuracy | ≤50Ωsound | ≤50Ωsound | ||
| Resolution | 0.01Ω | 0.01Ω | ||
| Loop power supply | Range | 24V | 24V | |
| Accuracy | ±10% | ±10% | ||
| The maximum current | 22mA | 22mA | ||
| HART | × | √ | ||
| Other functions | Backlight | √ | √ | |
| Auto Power-off | √ | √ | ||
| Charging function | √ | √ | ||
| Room temperature display | √ | √ | ||
| Battery detection | √ | √ | ||
| The ramp signal | √ | √ | ||
| Communication function | RS232 serial communication, can realize remote control instrument by the device driver software. | RS232 serial communication, can realize remote control instrument by the device driver software. | ||
| Characteristic | ||||
| Safety | EN61010-1:2001 | EN61010-1:2001 | ||
| Withstand voltage | The input and output AC350V/1 minutes | The input and output AC350V/1 minutes | ||
| Insulation | The input and output DC500V /50MΩ. | The input and output DC500V /50MΩ. | ||
| EMC | EN61326-1:2006 | EN61326-1:2006 | ||
| Authentication | CE | CE | ||
| Display | 3.2“ TFT screen | 3.2“ TFT screen | ||
| Power supply | 4×1.5V AA Alkaline battery | 4×1.5V AA Alkaline battery | ||
| Size | 206 × 97 × 60 mm | 206 × 97 × 60 mm | ||
| Weight | about 633g | about 633g | ||
| Standard Quantity Per Carton | 6pcs | 6pcs | ||
| Standard Carton Measurement | 530mm*405mm*310mm | 530mm*405mm*310mm | ||
| Standard Carton Cross Weight | 12.6kg | 12.6kg | ||







|   | 
| VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 Images | 
 2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                                                    
                        
                        
                        
                                                            2 Wire RTD Multifunction Process Calibrator Thermocouple Calibration Equipment
                                                    
                        
                     100MV Digital Signal Generator Analog Transmitter Source Simulator
                                                                                    
                        
                        
                        
                                                            100MV Digital Signal Generator Analog Transmitter Source Simulator
                                                    
                        
                     VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator
                                                                                    
                        
                        
                        
                                                            VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator
                                                    
                        
                     VICTOR 06 V/mA calibrator measure DCV DCA simulating output DC voltage, DC
                                                                                    
                        
                        
                        
                                                            VICTOR 06 V/mA calibrator measure DCV DCA simulating output DC voltage, DC
                                                    
                        
                     VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple
                                                                                    
                        
                        
                        
                                                            VICTOR 07 Temperature Calibrator Multi-function process calibrator thermocouple
                                                    
                        
                     VICTOR 01S Temperature Signal Generator Temperature Source process calibrator
                                                                                    
                        
                        
                        
                                                            VICTOR 01S Temperature Signal Generator Temperature Source process calibrator
                                                    
                        
                     VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument
                                                                                    
                        
                        
                        
                                                            VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument
                                                    
                        
                     RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
                                                                                    
                        
                        
                        
                                                            RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
                                                    
                        
                     VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator
                                                                                    
                        
                        
                        
                                                            VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator
                                                    
                        
                     High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator
                                                                                    
                        
                        
                        
                                                            High Precision Voltage Current Loop Calibrator Handheld Auto Signal Generator